I would run the wire along the bottom opposite side of metal roof of the 2x4 s that run perpendicular to the trusses.
Run romex through roof truss web.
Never ever drill through trusses.
Rigid conduit with an outside diameter of 3 4 in and a fish tape long enough to reach through the buried pipe.
That way the wire is in a protected underside corner where nothing could hang on top of it as it crosses the truss.
Straighten about 12 ft.
My attic is non accessible so i know for a fact that i must protect the romex with guard strips or bore holes 1 25 from the face of the joists when running perpendicular to the joists and when i run parallel i must staple the romex to the face of the joists.
Plus engineered structural members such as the bottom chord of roof trusses cannot be bored without an engineer s approval.
A where run across the top of floor joists.
Of cable and thread it through the holes from one box to the next.
Thread the cable through the holes.
Where run across the top of floor joists or within 2 1 m 7 ft of floor or floor joists across the face of rafters or studding in attics and roof spaces that are accessible the cable shall be protected by substantial guard strips that are at least as high as the cable.
One other way that nm cables in an attic become damaged is when a homeowner lays down boards or pieces of plywood directly over the cables compressing them against the top.
To run the wires inside rigid conduit you ll need a hacksaw a pipe bender capable of bending 1 2 in.
I did a lot of reading about it but am confused about the best way to do it.
So we most often see guard strips installed.
Use a splice box when installing.
Thursday february 13 2020 exposed nm nmc and nms cable are allowed to be run in one and two family dwellings their attached or detached garages and their storage buildings by the national electrical code nec 334 10 and 334 15.
Where run across the top of floor joists or within 2 1 m 7 ft of the floor or floor joists across the face of rafters or studding the cable shall be protected by substantial guard strips that are at least as high as the.
Can you run exposed nm cable romex in a garage.
Of wire they support.
Attics or roof spaces shall be installed as specified in 320 23 a and b.
The clips allow easy access if you need to run more wires and cost 40 for every 8 ft.
Of sheathed cable into the box and staple the cable photo 8.
When you reach each new box follow the stripping procedure shown in photo 7 push the conductors and about 1 4 in.
Some people might think that is expensive but this product is a tremendous time saver.
Pick a board that runs close to the corner webbing of the truss if possible.